Ionizing Air Nozzles Product |
SL-005 Ionizing Compressed Air Nozzle
SL-005A Ionizing Compressed Air Nozzle
SL-005B Ionizing Compressed Air Nozzle
SL-005C Ionizing Compressed Air Nozzle
SL-080A Ionizing Air Snake
SL-505 Ionizing Air Nozzle
|
|

|
SL-005 Ionizing Compressed Air Nozzle
SL-005 ionizing compressed air nozzle delivers ionization to neutralize charges in very specific area such as inaccessible trouble spot and hard to reach area to eliminate dust or contaminants and its re-attraction. It is ideally to be installed to a fixed work station in order to dissipate static charges automatically. Air nozzle has an effective area of 1,000mm.Itrequeres SL-007 power supply for operation which must be ordered separately. |
Specification:
Operating Voltage |
4.6KV |
Current Consumption |
200 ¦Ì A |
Operating Temperature |
0~50 ¡æ |
Weight |
0.4kg |
H £® V Cable |
3Metres |
Air pressure |
40-70psi |
Air Velocity |
10m/sec |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 4.6KV
Testing Voltage£º 5kV to 500V
Temperature £º 22 ¡æ |
Distance |
| 300mm |
900mm |
1500mm |
Decay time |
Positive(+) |
0.1s |
0.2s |
0.9s |
| |
Negative (-) |
0.1s |
0.2s |
0.7s |
Offset voltage |
Positive(+) |
-28V |
-18V |
+19V |
| |
Negative(-) |
-29V |
-17V |
+18V |
Remarks:
1. Air velocity measured at 150mm.
2. Operational ionizing distance of 150mm.
Top | Back |
|

|
SL-005A Ionizing Compressed Air Nozzle
SL-005A Ionizing compressed air nozzle delivers ionization to neutralize charges in very specific area such as inaccessible trouble spot and hard to reach area to eliminate dust or contaminants and its re-attraction. It is ideally to be installed to a fixed work station in order to dissipate static charges automatically. Air nozzle has an effective area lf 1,000mm.It requires SL-009A power supply for operation which must be ordered separately. |
Specification:
Operating Voltage |
7 KV |
Current Consumption |
200 ¦Ì A |
Operating Temperature |
0~50 ¡æ |
Weight |
0.5kg |
H £® V Cable |
3Metres |
Air pressure |
40-70psi |
Air Velocity |
10m/sec |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 4.6KV
Testing Voltage£º 5kV to 500V
Temperature £º 22 ¡æ |
Distance |
| 300mm |
900mm |
1500mm |
Decay time |
Positive(+) |
0.1s |
0.2s |
0.9s |
| |
Negative (-) |
0.1s |
0.2s |
0.7s |
Offset voltage |
Positive(+) |
-28V |
-18V |
+19V |
| |
Negative(-) |
-29V |
-17V |
+18V |
Top | Back |
|

|
SL-005B Ionizing Compressed Air Nozzle
SL-005B ionizing Compressed air nozzle delivers ionization to neutralize charges in very specific area such as inaccessible trouble spot and hard to reach area to eliminate dust or contaminants and its re-attraction. It is ideally to be installed to a fixed work station in order to dissipate static charges automatically. Air nozzle has an effective area of 1,000mm..It requires SL-008 power Supply for operation which must be ordered separately. |
Specification:
Operating Voltage |
5.6kv |
Current Consumption |
200 ¦Ì A |
Operating Temperature |
0~50 ¡æ |
Weight |
0.4kg |
H £® V Cable |
3Metres |
Air pressure |
40-70psi |
Air Velocity |
10m/sec |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 4.6KV
Testing Voltage£º 5kV to 500V
Temperature £º 22 ¡æ |
Distance |
| 300mm |
900mm |
1500mm |
Decay time |
Positive(+) |
0.1s |
0.2s |
0.9s |
| |
Negative (-) |
0.1s |
0.2s |
0.7s |
Offset voltage |
Positive(+) |
-28V |
-18V |
+19V |
| |
Negative(-) |
-29V |
-17V |
+18V |
Remarks:
1. Air velocity measured at 150mm.
2. Operational ionizing distance of 150mm.
Top | Back |
|
|
SL-005C Ionizing Compressed Air Nozzle
SL-005C ionizing compressed air nozzle delivers ionization to neutralize charges in very specific area such as inaccessible trouble spot and hard to reach area to eliminate dust or contaminants and its re-attraction. It is a hand free flexible ionizing nozzle that can be positioned to produce a clean ionized stream to a targeted surface. It is ideally to be installed to a fixed work station in order to dissipate static charges automatically. Air nozzle has an effective area of 1,000mm.Itrequeres SL-007 power supply for operation which must be ordered separately. |
Specification:
Operating Voltage |
4.6kv |
Current Consumption |
200 ¦Ì A |
Operating Temperature |
0~50 ¡æ |
Weight |
0.6kg |
H.V Cable |
3Metres |
Air pressure |
40-70psi |
Air Velocity |
10m/sec |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 4.6KV
Testing Voltage£º 5kV to 500V
Temperature £º 22 ¡æ |
Distance |
| 300mm |
900mm |
1500mm |
Decay time |
Positive(+) |
0.1s |
0.2s |
0.9s |
| |
Negative (-) |
0.1s |
0.2s |
0.7s |
Offset voltage |
Positive(+) |
-28V |
-18V |
+19V |
| |
Negative(-) |
-29V |
-17V |
+18V |
Remarks:
1. Air velocity measured at 150mm.
2. Operational ionizing distance of 150mm.
Top | Back |
|
 |
SL-080A Ionizing Air Snake
SL-080A Ionizing Air Snake can neutralize charges and eliminate dust in inaccessible trouble spot and hard to reach area. It is a hand free flexible ionizing nozzle that can be positioned to produce a clean ionized stream to a targeted surface. Powered by the Air Flow Controller, it can be placed anywhere. The emitters can be easily replaced. It requires SL-007power supply for operation which must be ordered separately. It may operate with a foot pedal for on/off air control.
|
Specification:
Operating Voltage |
4.6KV |
Current Consumption |
350 ¦Ì A |
Operating Temperature |
0~50 ¡æ |
Weight |
0.7kg |
Length of hose |
33cm |
Material |
polypropylene flex hose |
Air pressure |
5~70psi |
Air Velocity |
10m/sec |
Air Flow |
0.8 SCFM at 10 PSI
5.5 SCFM at 50 PSI
11.5 SCFM at 100PSI |
Discharge Time (5000V to 500V at 15cm) |
£¼ 2seconds |
Top | Back |
|
|
SL-505 Ionizing Air Nozzle
Ionizing compressed air nozzles are mounted on a delivers ionization to neutralize charges in specific target such as inaccessible trouble spot. It is ideally installed to a fixed work station in order to dissipate static charges automatically. It has an effective area of 1,000mm. It needs to be operated by power supply which is ordered separately. It can be customized by many different configurations.
Features:
1. can be installed on a fixed position,
2. airflow pinpoints more than a spot area at the mean time.
|
|
|
Top | Back |
| |