Netvigation
Company Profile
Our Company Vision and Mission
Product Showcase
List of our product in detail
Our Clients
Our clients list in detail
Service/Contact Us
Our Service and Contact us
News
Detail News

Home



Ionizing Air Blowers Product

SL-001 Bench Top Ionizing Air Blower DC-001 Bench Top Ionizing Air Blower
SL-002 Overhead Ionizing Blower DC-001A Warming Air Function Ionizing Air Blower
SL-003 Overhead Ionizing Air Blower DC-003 Overhead Ionizing Air Blower
SL-010 Horizontal Ionizing Air Bower DC-110 Ionizing Air Blower
SL-020 Bench Top Ionizing Blower FC-001 Bench Top Ionizing Air Blower
SL-025 Bench Top Ionizing Air Blower ZH-001 Bench Top Ionizing Air Blower
SL-028 Bench Top Ionizing Air Blower ZH-002 Overhead Ionizing Blower
SL-090 Static Elimination Blower ZH-003 Overhead Ionizing Air Blower
SL-095 Static Elimination Blower ZH-028 Bench Top Ionizing Air Blower
SL-111D Mini Ionizing Air Blower XG-001 Bench Top Ionizing Air Blower
SL-220 Bench Top Ionizing Air Blower XG-002 Overhead Ionizing Blower
SL-801D Warning Ionizing Air Blower XG-003 Overhead Ionizing Air Blower
SL-821 Warning Ionizing Air Blower XG-028 Bench Top Ionizing Air Blower
SL-900 Ionizing Air Controller GH-2000 Bench Top Ionizing Air Blower
SL-1104 Overhead Ionizing Air Blower GH-3000 Bench Top Ionizing Air Blower


SL-001 Bench Top Ionizing Air Blower

Dr.Schneider SL-001 Bench Top Ionizing Air Blower is a static elimination device which delivers a balanced ion stream to neutralize wide, focused areas. It removes contaminants attraction and neutralizes static charges from wide, focused, or hard to reach areas so as to increase productivity and yield in manufacturing. It is ideally used in industrial environments such as delicate electronic products, electronic assembly line, medical device manufacturing and assembly lines, printing, packaging, and small part injection molding. SL-001 is a portable ionizing air blower. Its features are quickly neutralizes static charges, build-in emitter cleaner, adjustable air flow speed control, indicator light for presence of ionization, integrated blower and power supply.

Specification:

Operating Voltage:

110V/60Hz or220V/50Hz

Current Consumption:

0.25A or 0.12A

Operating Temperature:

0~50 ¡æ

Air Coverage:

40cm ¡Á 60cm

Size:

90mm(L) ¡Á 260mm(H) ¡Á 170mm(W)

Weight:

3kg

Air Volume:

45~110CFM

Ion Balance:

0V ¡À 5V

Decay Test Results:

Testing Conditions

Operating Voltage£º 4.6KV
Testing Voltage£º 5kV to 500V
Temperature £º 22 ¡æ

Distance

 

300mm

600mm

900mm

Decay time

Positive(+)

1.0s

2.1s

3.7s

Negative (-)

1.0s

2.5s

3.8s

Offset voltage

Positive(+)

5V

5V

4V

Negative(-)

4V

4V

3V

Top | Back


SL-002 Overhead Ionizing Blower

SL-002 blower is an overhead designed unit to provide wide coverage for electrostatic problems. It removes contaminants attraction and neutralizes static charge from wide, focused, or hard to reach area so as to increase productivity and yield in manufacturing. It is ideally used in industrial environments, such as delicate electronic products, electronic assembly line, medical device manufacturing and assemble lines, printing, packaging and small parts injection molding. Its features are quickly two airflow output, build-in emitter cleaner, adjustable air flow speed control, indicator light for presence of ionization, integrated blower and power supply.

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

0.9A or 0.4A

Operating Temperature

0~50 ¡æ

Air Coverage

40cm ¡Á 90cm

Size

610mm(L) ¡Á 120mm(H) ¡Á 180mm(W)

Weight

8kg

Air Volume

80~220CFM

Ion Balance

0V ¡À 5V

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1kV to 100V
Temperature£º 22 ¡æ

Distance

300mm

600mm

900mm

1200mm

Left 300mm

0.7s

2.1s

3.2s

4.0s

Center

0.6s

1.9s

2.5s

3.5s

Right 300mm

0.7s

2.0s

2.9s

3.9s

Top | Back


SL-003 Overhead Ionizing Air Blower

SL-003 blower is an overhead designed unit to provide total coverage for electrostatic problems. It removes contaminants attraction and neutralizes static charges from wide, focused, or hard to reach areas so as to increase productivity and yield in manufacturing. It is ideally used in industrial environments such as delicate electronic products, electronic assembly line, medical device manufacturing and assembly lines, printing, packaging, and small part injection molding. Its features are three airflow output, build-in emitter cleaner, adjustable speed control for airflow, indicator light for presence of ionization, integrated blower and power supply.

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

1.25A or 0.62A

Operating Temperature

0~50 ¡æ

Air Coverage

40cm ¡Á 120cm

Size

1100mm(L) ¡Á 110mm(H) ¡Á 184mm(W)

Weight

11.7kg

Air Volume

120~330CFM

Ion Balance

0V ¡À 5V

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ

Distance

300mm

600mm

900mm

1200mm

Left 300mm

0.6s

2.1s

4.9s

6.1s

Centre

0.6s

1.9s

4.2s

5.7s

Right 300mm

0.7s

2.1s

4.7s

6.0s

Top | Back


SL-010 Ionizing Air Bower

SL-010 is a device which produces maximum air volume in bench top static eliminator series. It neutralizes charge over large targeted surface especially in plastic sheet fabrication and vacuum forming. Air volume is ranging from 45~190CFM. Ion balance voltage is 0V (+/- 5V).

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

3A or 1.5A

Operating Temperature

0~50 ¡æ

Air Coverage

60cm ¡Á 120cm

Size

570mm(L) ¡Á 190mm(H) ¡Á 225mm(W)

Weight

8.8kg

Air Volume

45~190CFM

Ion Balance 0V ¡À 5V

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ

Distance

300mm

600mm

900mm

1200mm

Left 300mm

0.7s

1.4s

4.0s

7.6s

Centre

0.6s

1.3s

3.5s

7.4s

Right 300mm

0.8s

1.3s

3.7s

7.9s

Top | Back


SL-020 Bench Top Ionizing Blower

SL-020 is a device which produces maximum air volume in bench top static eliminator series. It neutralizes charge over large targeted surface especially in plastic sheet fabrication and vacuum forming. Air volume is ranging from 70~120CFM.Ion balance voltage is 0v(+/-5 v)

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

3.0 A or 1.5A

Operating Temperature

0~50 ¡æ

Size

450mm(L) ¡Á 225mm(H) ¡Á 190mm(W)

Weight

7.5kg

Air Coverage 60cm ¡Á 120cm

Air Volume

70~120CFM

Ion Balance 0V ¡À 10V

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ

Distance

300mm

600mm

900mm

1200mm

Left 300mm

0.9s

1.9s

3.5s

5.9s

Centre

0.8s

1.5s

3.0s

5.4s

Right 300mm

0.9s

1.8s

3.3s

5.8s

Top | Back


SL-025 Bench Top Ionizing Blower

--------

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

3.0 A or 1.5A

Operating Temperature

0~50 ¡æ

Size

510mm(L) ¡Á 150mm(H) ¡Á 220mm(W)

Weight

8kg

Air Coverage 50cm ¡Á 120cm

Air Volume

70~120CFM

Ion Balance 0V ¡À 5V

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ

Distance

300mm

600mm

900mm

1200mm

Left 300mm

1.1s

2.8s

3.9s

5.6s

Centre

1.0s

2.2s

3.6s

5.5s

Right 300mm

1.2s

2.8s

3.8s

5.9s

Top | Back


SL-028 Bench Top Ionizing Blower

SL-028 is a device which produces maximum air volume in bench top static eliminator series. It neutralizes charge over large targeted surface especially in plastic sheet fabrication and vacuum forming. Air volume is ranging from 70~120CFM.Ion balance voltage is 0v(+/-5 v)

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

3.0 A or 1.5A

Operating Temperature

0~50 ¡æ

Size

450mm(L) ¡Á 225mm(H) ¡Á 190mm(W)

Weight

8.5kg

Air Coverage 60cm ¡Á 120cm

Air Volume

70~120CFM

Ion Balance 0V ¡À 10V

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ

Distance

300mm

600mm

900mm

1200mm

Left 300mm

0.9s

1.9s

3.5s

5.9s

Centre

0.8s

1.5s

3.0s

5.4s

Right 300mm

0.9s

1.8s

3.3s

5.8s

Top | Back


SL-090 Static Elimination Blower

It provides heavy duty, extended range static elimination. It is most ideally used in extremely stubborn static charge working or production area.

Specification:

Power Requirements

220V/50Hz 380/50Hz 3Phase

Current Consumption

1.4A/2.3A

Operating Temperature

0~50 ¡æ

Air Coverage 60cm ¡Á 300cm
Integrated Power Supply 7.0Kv

Size

547mm(L) ¡Á 360mm(W) ¡Á 230mm(H)

Weight

17.5kg

Air Volume

335~410CFM

Discharge Time (5000V~500V at 30cm) <1 sec (Fan speed high )
Ion Balance 0V ¡À 10V

Top | Back


SL-095 Static Elimination Blower

Features:
shockless designed,
easy install in machinery,
quickly neutralize static charges,
operate with power supply.

Decay Test Results:

Decay Time

Offset Voltage

5000V to 500V (Distance 300mm <2.0sec)

0V¡À20V

Top | Back


SL-111D Mini Ionizing Air Blower

Features:
The body is light and small,
Quickly neutralize static charges,
Ergonomic designed,
Most suitable for constrained working area.

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

0.7A or 0.3A

Limited Power

¨Q3.6W

Operating Temperature

32¨H (0¡æ) ~ 122¨H (50¡æ)

Air Coverage

120mm x 120mm x 350mm

Weight

Switch Box: 0.75kg
Blower: 0.28kg
Stand: 1.20kg

Size

85mm (L) x 25mm (W) x 105 mm (H)

Top | Back


SL-220 Bench Top Ionizing Blower

---

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

3.0 A or 1.5A

Operating Temperature

0~50 ¡æ

Size

430mm(L) ¡Á 155mm(H) ¡Á 200mm(W)

Weight

6.5kg

Air Coverage 60cm ¡Á 120cm

Air Volume

70~120CFM

Ion Balance 0V ¡À 5V

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ

Distance

300mm

600mm

900mm

1200mm

Left 300mm

1.1s

2.8s

3.9s

5.6s

Centre

1.0s

2.2s

3.6s

5.5s

Right 300mm

1.2s

2.8s

3.8s

5.9s

Top | Back


SL-801D Warning Ionizing Air Blower

Features:
Portable, light
Quiet, ionization indicator, airflow speed Control
Warning function: It buzzes as ion balance higher than +/-25V. It can be amended according to customer request.
Air coverage 300mm ¡Á 300mm ¡Á 900mm,
Apply to internal machinery, working bench, assembly line, etc.

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

0.12 A or 0.05A

Operating Temperature

32F(0 ¡æ)~122F(50 ¡æ )

Air Coverage

30cm¡Á30cm

Size

133mm(L) ¡Á 62mm(W) ¡Á 175mm(H)

Weight

2.0kg

Air Volume

50~90CFM

Limited Power

¨Q15W

Ion Balance 0V ¡À 5V

Decay Test Results:

Distance

Decay Time

 

300mm

0.8s

 

600mm

1.7s

 

900mm

4.3s

 

Top | Back


SL-821 Warning Ionizing Air Blower

Features:
Portable, light
Quiet, ionization indicator
Warning function: It buzzes as ion balance higher than +/-25V. It can be amended according to customer request.
Air coverage 300mm ¡Á 300mm ¡Á 900mm,
Apply to internal machinery, working bench, assembly line, etc.

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

0.13Aor 0.06A

Operating Temperature

32F(0 ¡æ)~122F(50 ¡æ )

Air Coverage

30cm ¡Á 30cm

Size

195mm(L) ¡Á 88mm(W) ¡Á 236mm(H)

Weight

1.66kg

Air Volume

50~90CFM

Limited Power

¨Q15W

Ion Balance 0V ¡À 5V

Decay Test Results:

Distance

Decay Time

 

300mm

0.8s

 

600mm

1.7s

 

900mm

4.3s

 

Top | Back


SL-900 Ionizing Air Controller

Dr Schneider Ionizing Air Controller not only can be applied to eliminate static charge on targeted objects, but also to purify the air quickly and effectively. The effective area is about 12m2. It is most applicable in cleanroom or laboratory.

Specification:

Operating Voltage

220V ac 50Hz

Current Consumption

¨Q0.95A

Air Volocity 2-8m3
Air Coverage 12m3

Operating Temperature

32¨H (0¡æ) - 122 ¨H(50¡æ)

Noise

<52dB

Casing

Plastic

Weight

11kg

Size

41cm (L) x 33cm (W) x 81cm (H)

Ionizing Balance 0V ~ ¡À10V

Decay Test Results:

Testing Conditions

Air Flow

 

Centre to Left 300mm

Centre

Cemtre tp Right 300mm

Low

Positive

1.3s

0.9s

1.3s

Negative

1.6s

1.2s

1.6s

Medium

Positive

1.1s

0.9s

1.1s

Negative

1.4s

1.0s

1.4s

High

Positive

0.8s

0.6s

0.8s

Negative

1.0s

0.7s

1.0s

Top | Back


SL-1104 Overhead Ionizing Air Blower

---

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

1.66AMP or 0.83AMP

Operating Temperature

0~50 ¡æ

Size

1100mm(L) ¡Á 110mm(H) ¡Á 184mm(W)

Weight

11.7kg

Air Coverage 40cm ¡Á 120cm

Air Volume

160~330CFM

Ion Balance 0V ¡À 5V

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ

Distance

300mm

600mm

900mm

1200mm

Left 300mm

0.6s

2.1s

4.9s

6.1s

Centre

0.6s

1.9s

4.2s

5.7s

Right 300mm

0.7s

2.1s

4.7s

6.0s

Remarks:
1.Distance measured in mm, decay time measured in seconds.
2.Test data available using ME 268A Charged Plate Analyzer.
3.Test figures are subject to variation in the atmospheric conditions.

Top | Back


DC-001 Bench Top Ionizing Air Blower

Quickly neutralizes static charges, Excellent ion balance, Build ¨Cin emitter cleaner, Light and compact, it suits for machinery internal, working bench and production line.

Specification:

Operating Voltage

In: 220V Out: 15V

Current Consumption

220VAC/0.06A

Operating Temperature

0~50¡æ

Air Speed 2.0~3.3m/second

Size

180mm (L) x 200mm (H) x 75mm (W)

Weight

1.0kg

Ozone Density £¼ 0.007ppm
Ion Balance 0V ¡À 5V
Noise 55dB
Air Volume Low 50CFM 2.5m/s
High 90CFM 4.0m/s

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1KVto 100V
Temperature £º 22 ¡æ

Distance

300mm

600mm

900mm

Decay time

0.5s-0.9s

1.4s-1.8s

4.0s-4.5s

Top | Back


DC-001A Warming Air Function Ionizing Air Blower

Specification:

Operating Voltage

110V/60Hz, 220V/50Hz

Current Consumption

2.1A or 4.2A

Operating Temperature

32¨H(0¡æ) ~ 122¨H(50¡æ)

Air Coverage 30cm x 30cm

Size

240mm (L) x 180mm (W) x 100mm (H)

Weight

1.8kg

Air Volume 50CFM~90CFM
Limited Power 315W
Ion Balance 0V¡À10V

Top | Back


DC-003 Overhead Ionizing Air Blower

Features:
Operating with DC current,
More light,
Three airflow output.

Specification:

Operating Voltage

110V/60Hz,220V/50Hz

Current Consumption

1.66A or 0.83A

Operating Temperature

0~50¡æ

Air Coverage 40cm x 120cm

Size

1180mm (L) x 155mm (W) x 110mm (H)

Weight

10kg

Air Volume 160~330CFM
Ion Balance 0V ¡À 5V

Decay Test Results:

Distance

Discharge Time

Offset Volt

300mm

0.9s

¡À 5V

600mm

2.4s

¡À 5V

900mm

4.5s

¡À 5V

Top | Back


DC-110 Ionizing Air Blower

Specification:

Operating Voltage

110V/60Hz,220V/50Hz

Current Consumption

3.2A or 1.6A

Operating Temperature

0~50¡æ

Size

420mm (L) x 160mm (W) x 170mm (H)

Weight

5.6kg

Coverage Range 80cm x 120cm
Ion Balance 0V ¡À 5V
Air Volume 70~120CFM

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1KVto 100V
Temperature £º 22 ¡æ

Distance

300mm

600mm

900mm

Positive (+)

0.9s

2.1s

3.5s

Negative (-)

1.0s

2.3s

3.8s

Top | Back


FC-001 Bench Top Ionizing Air Blower

Features:
Quickly neutralizes static charges
Excellent ion balance
Build-in emitter cleaner
Light and compact,
it suits for machinery internal, working bench and production line.

Specification:

Operating Voltage

90V-264V

Current Consumption

0.5A

Operating Temperature

0¡æ ~40¡æ

Air Coverage 300mm ¡Á 300mm
Air Volocity 90~120CFM

Size

75mm(L) ¡Á 160mm(W) ¡Á 200mm(H)

Weight

0.8kg

Ozone Density £¼0.007ppm
Ion Balance 0V ¡À 5V

Limited Power

¡Ü10W

Decay Test Results:

Testing Conditions

Operating Voltage£º 90V/264V
Testing Voltage£º 1KV ~ 100V
Temperature £º 22 ¡æ
Rh£º 55 ~70%

Distance

 

300mm

600mm

900mm

Decay time

Positive(+)

1.5s

3.1s

3.5s

Negative (-)

1.7s

3.4s

4.0s

Remarks:
1. Distance measured in mm, decay time measured in seconds.
2. Test data available using ME 268A Charged Plate Analyzer.
3. Test figures are subject to variation in the atmospheric conditions.

Top | Back


ZH-001 Bench Top Ionizing Air Blower

ZHEN HUA ZH-001 Bench Top Ionizing Air Blower is static elimination device which deliver a balanced ion stream to neutralize wide, focused areas. It removes contaminants attraction and neutralize static charges from wide, focused, or hard to reach areas so as to increase productivity and yield in manufacturing. It is ideally used in industrial environments such as delicate electronic products, electronic assembly line, medical device manufacturing and assembly lines, printing, packaging, and small part injection molding. Its features are quickly neutralizes static charges, build-in emitter cleaner, adjustable speed control for airflow, indicator light for presence of ionization, integrated blower and power supply. The desk-top ionizing blower is a portable ionized air blower. It uses a small fan to produce air flow. The volume of air flow is controlled by a variable speed control which provides a wide range of air flow setting.

Specification:

Operating Voltage

110V/60Hz or220V/50Hz

Current Consumption

0.25A or 0.12A

Operating Temperature

0~50 ¡æ

Air Coverage 40cm ¡Á 60cm

Size

90mm(L) ¡Á 260mm(H) ¡Á 170mm(W)

Weight

3kg

Air Volume 45~110CFM
Ion Balance +/- 10V

Decay Test Results:

Testing Conditions

Operating Voltage£º 110V/220V
Testing Voltage£º 1KVto 100V
Temperature £º 22 ¡æ