Ionizing Air Blowers Product |
|
|
|
SL-001 Bench Top Ionizing Air Blower
Dr.Schneider SL-001 Bench Top Ionizing Air Blower is a static elimination device which delivers a balanced ion stream to neutralize wide, focused areas. It removes contaminants attraction and neutralizes static charges from wide, focused, or hard to reach areas so as to increase productivity and yield in manufacturing. It is ideally used in industrial environments such as delicate electronic products, electronic assembly line, medical device manufacturing and assembly lines, printing, packaging, and small part injection molding. SL-001 is a portable ionizing air blower. Its features are quickly neutralizes static charges, build-in emitter cleaner, adjustable air flow speed control, indicator light for presence of ionization, integrated blower and power supply. |
Specification:
Operating Voltage: |
110V/60Hz or220V/50Hz |
Current Consumption: |
0.25A or 0.12A |
Operating Temperature: |
0~50 ¡æ |
Air Coverage: |
40cm ¡Á 60cm |
Size: |
90mm(L) ¡Á 260mm(H) ¡Á 170mm(W) |
Weight: |
3kg |
Air Volume: |
45~110CFM |
Ion Balance: |
0V ¡À 5V |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 4.6KV
Testing Voltage£º 5kV to 500V
Temperature £º 22 ¡æ |
Distance |
|
300mm |
600mm |
900mm |
Decay time |
Positive(+) |
1.0s |
2.1s |
3.7s |
| |
Negative (-) |
1.0s |
2.5s |
3.8s |
Offset voltage |
Positive(+) |
5V |
5V |
4V |
| |
Negative(-) |
4V |
4V |
3V |
Top | Back |
|
|
SL-002 Overhead Ionizing Blower
SL-002 blower is an overhead designed unit to provide wide coverage for electrostatic problems. It removes contaminants attraction and neutralizes static charge from wide, focused, or hard to reach area so as to increase productivity and yield in manufacturing. It is ideally used in industrial environments, such as delicate electronic products, electronic assembly line, medical device manufacturing and assemble lines, printing, packaging and small parts injection molding. Its features are quickly two airflow output, build-in emitter cleaner, adjustable air flow speed control, indicator light for presence of ionization, integrated blower and power supply. |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
0.9A or 0.4A |
Operating Temperature |
0~50 ¡æ |
Air Coverage |
40cm ¡Á 90cm |
Size |
610mm(L) ¡Á 120mm(H) ¡Á 180mm(W) |
Weight |
8kg |
Air Volume |
80~220CFM |
Ion Balance |
0V ¡À 5V |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1kV to 100V
Temperature£º 22 ¡æ |
Distance |
300mm |
600mm |
900mm |
1200mm |
Left 300mm |
0.7s |
2.1s |
3.2s |
4.0s |
Center |
0.6s |
1.9s |
2.5s |
3.5s |
Right 300mm |
0.7s |
2.0s |
2.9s |
3.9s |
Top | Back |
|

SL-003 Overhead Ionizing Air Blower
SL-003 blower is an overhead designed unit to provide total coverage for electrostatic problems. It removes contaminants attraction and neutralizes static charges from wide, focused, or hard to reach areas so as to increase productivity and yield in manufacturing. It is ideally used in industrial environments such as delicate electronic products, electronic assembly line, medical device manufacturing and assembly lines, printing, packaging, and small part injection molding. Its features are three airflow output, build-in emitter cleaner, adjustable speed control for airflow, indicator light for presence of ionization, integrated blower and power supply. |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
1.25A or 0.62A |
Operating Temperature |
0~50 ¡æ |
Air Coverage |
40cm ¡Á 120cm |
Size |
1100mm(L) ¡Á 110mm(H) ¡Á 184mm(W) |
Weight |
11.7kg |
Air Volume |
120~330CFM |
Ion Balance |
0V ¡À 5V |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ |
Distance |
300mm |
600mm |
900mm |
1200mm |
Left 300mm |
0.6s |
2.1s |
4.9s |
6.1s |
Centre |
0.6s |
1.9s |
4.2s |
5.7s |
Right 300mm |
0.7s |
2.1s |
4.7s |
6.0s |
Top | Back |
|

SL-010
Ionizing Air Bower
SL-010 is a device which produces maximum air volume in bench top static eliminator series. It neutralizes charge over large targeted surface especially in plastic sheet fabrication and vacuum forming. Air volume is ranging from 45~190CFM. Ion balance voltage is 0V (+/- 5V). |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
3A or 1.5A |
Operating Temperature |
0~50 ¡æ |
Air Coverage |
60cm ¡Á 120cm |
Size |
570mm(L) ¡Á 190mm(H) ¡Á 225mm(W) |
Weight |
8.8kg |
Air Volume |
45~190CFM |
| Ion Balance |
0V ¡À 5V |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ |
Distance |
300mm |
600mm |
900mm |
1200mm |
Left 300mm |
0.7s |
1.4s |
4.0s |
7.6s |
Centre |
0.6s |
1.3s |
3.5s |
7.4s |
Right 300mm |
0.8s |
1.3s |
3.7s |
7.9s |
Top | Back |
|
 |
SL-020
Bench Top Ionizing Blower
SL-020 is a device which produces maximum air volume in bench top static eliminator series. It neutralizes charge over large targeted surface especially in plastic sheet fabrication and vacuum forming. Air volume is ranging from 70~120CFM.Ion balance voltage is 0v(+/-5 v) |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
3.0 A or 1.5A |
Operating Temperature |
0~50 ¡æ |
Size |
450mm(L) ¡Á 225mm(H) ¡Á 190mm(W) |
Weight |
7.5kg |
| Air Coverage |
60cm ¡Á 120cm |
Air Volume |
70~120CFM |
| Ion Balance |
0V ¡À 10V |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ |
Distance |
300mm |
600mm |
900mm |
1200mm |
Left 300mm |
0.9s |
1.9s |
3.5s |
5.9s |
Centre |
0.8s |
1.5s |
3.0s |
5.4s |
Right 300mm |
0.9s |
1.8s |
3.3s |
5.8s |
Top | Back |
|

SL-025 Bench Top Ionizing Blower -------- |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
3.0 A or 1.5A |
Operating Temperature |
0~50 ¡æ |
Size |
510mm(L) ¡Á 150mm(H) ¡Á 220mm(W) |
Weight |
8kg |
| Air Coverage |
50cm ¡Á 120cm |
Air Volume |
70~120CFM |
| Ion Balance |
0V ¡À 5V |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ |
Distance |
300mm |
600mm |
900mm |
1200mm |
Left 300mm |
1.1s |
2.8s |
3.9s |
5.6s |
Centre |
1.0s |
2.2s |
3.6s |
5.5s |
Right 300mm |
1.2s |
2.8s |
3.8s |
5.9s |
Top | Back |
|
 |
SL-028 Bench Top Ionizing Blower
SL-028 is a device which produces maximum air volume in bench top static eliminator series. It neutralizes charge over large targeted surface especially in plastic sheet fabrication and vacuum forming. Air volume is ranging from 70~120CFM.Ion balance voltage is 0v(+/-5 v) |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
3.0 A or 1.5A |
Operating Temperature |
0~50 ¡æ |
Size |
450mm(L) ¡Á 225mm(H) ¡Á 190mm(W) |
Weight |
8.5kg |
| Air Coverage |
60cm ¡Á 120cm |
Air Volume |
70~120CFM |
| Ion Balance |
0V ¡À 10V |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ |
Distance |
300mm |
600mm |
900mm |
1200mm |
Left 300mm |
0.9s |
1.9s |
3.5s |
5.9s |
Centre |
0.8s |
1.5s |
3.0s |
5.4s |
Right 300mm |
0.9s |
1.8s |
3.3s |
5.8s |
Top | Back |
|
 |
SL-090 Static Elimination Blower
It provides heavy duty, extended range static elimination. It is most ideally used in extremely stubborn static charge working or production area. |
Specification:
Power Requirements |
220V/50Hz 380/50Hz 3Phase |
Current Consumption |
1.4A/2.3A |
Operating Temperature |
0~50 ¡æ |
| Air Coverage |
60cm ¡Á 300cm |
| Integrated Power Supply |
7.0Kv |
Size |
547mm(L) ¡Á 360mm(W) ¡Á 230mm(H) |
Weight |
17.5kg |
Air Volume |
335~410CFM |
| Discharge Time (5000V~500V at 30cm) |
<1 sec (Fan speed high ) |
| Ion Balance |
0V ¡À 10V |
|
|
Top | Back |
|
 |
SL-095 Static Elimination Blower
Features:
shockless designed,
easy install in machinery,
quickly neutralize static charges,
operate with power supply. |
Decay Test Results:
Decay Time |
Offset Voltage |
5000V to 500V (Distance 300mm <2.0sec) |
0V¡À20V |
Top | Back |
|
 |
SL-111D Mini Ionizing Air Blower
Features:
The body is light and small,
Quickly neutralize static charges,
Ergonomic designed,
Most suitable for constrained working area. |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
0.7A or 0.3A |
Limited Power |
¨Q3.6W |
Operating Temperature |
32¨H (0¡æ) ~ 122¨H (50¡æ) |
Air Coverage |
120mm x 120mm x 350mm |
Weight |
Switch Box: 0.75kg Blower: 0.28kg Stand: 1.20kg |
Size |
85mm (L) x 25mm (W) x 105 mm (H) |
|
|
Top | Back |
|
 |
SL-220 Bench Top Ionizing Blower
--- |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
3.0 A or 1.5A |
Operating Temperature |
0~50 ¡æ |
Size |
430mm(L) ¡Á 155mm(H) ¡Á 200mm(W) |
Weight |
6.5kg |
| Air Coverage |
60cm ¡Á 120cm |
Air Volume |
70~120CFM |
| Ion Balance |
0V ¡À 5V |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ |
Distance |
300mm |
600mm |
900mm |
1200mm |
Left 300mm |
1.1s |
2.8s |
3.9s |
5.6s |
Centre |
1.0s |
2.2s |
3.6s |
5.5s |
Right 300mm |
1.2s |
2.8s |
3.8s |
5.9s |
Top | Back |
|
 |
SL-801D Warning Ionizing Air Blower
Features:
Portable, light
Quiet, ionization indicator, airflow speed Control
Warning function: It buzzes as ion balance higher than +/-25V. It can be amended according to customer request.
Air coverage 300mm ¡Á 300mm ¡Á 900mm,
Apply to internal machinery, working bench, assembly line, etc. |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
0.12 A or 0.05A |
Operating Temperature |
32F(0 ¡æ)~122F(50 ¡æ ) |
Air Coverage |
30cm¡Á30cm |
Size |
133mm(L) ¡Á 62mm(W) ¡Á 175mm(H) |
Weight |
2.0kg |
Air Volume |
50~90CFM |
Limited Power |
¨Q15W |
| Ion Balance |
0V ¡À 5V |
|
Decay Test Results:
Distance |
Decay Time |
|
300mm |
0.8s |
|
600mm |
1.7s |
|
900mm |
4.3s |
|
Top | Back |
|
 |
SL-821 Warning Ionizing Air Blower
Features:
Portable, light
Quiet, ionization indicator
Warning function: It buzzes as ion balance higher than +/-25V. It can be amended according to customer request.
Air coverage 300mm ¡Á 300mm ¡Á 900mm,
Apply to internal machinery, working bench, assembly line, etc. |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
0.13Aor 0.06A |
Operating Temperature |
32F(0 ¡æ)~122F(50 ¡æ ) |
Air Coverage |
30cm ¡Á 30cm |
Size |
195mm(L) ¡Á 88mm(W) ¡Á 236mm(H) |
Weight |
1.66kg |
Air Volume |
50~90CFM |
Limited Power |
¨Q15W |
| Ion Balance |
0V ¡À 5V |
|
Decay Test Results:
Distance |
Decay Time |
|
300mm |
0.8s |
|
600mm |
1.7s |
|
900mm |
4.3s |
|
Top | Back |
|

|
SL-900 Ionizing Air Controller
Dr Schneider Ionizing Air Controller not only can be applied to eliminate static charge on targeted objects, but also to purify the air quickly and effectively. The effective area is about 12m2. It is most applicable in cleanroom or laboratory.
|
Specification:
Operating Voltage |
220V ac 50Hz |
Current Consumption |
¨Q0.95A |
| Air Volocity |
2-8m3 |
| Air Coverage |
12m3 |
Operating Temperature |
32¨H (0¡æ) - 122 ¨H(50¡æ) |
Noise |
<52dB |
Casing |
Plastic |
Weight |
11kg |
Size |
41cm (L) x 33cm (W) x 81cm (H) |
| Ionizing Balance |
0V ~ ¡À10V |
|
Decay Test Results:
Testing Conditions |
Air Flow |
|
Centre to Left 300mm |
Centre |
Cemtre tp Right 300mm |
Low |
Positive |
1.3s |
0.9s |
1.3s |
Negative |
1.6s |
1.2s |
1.6s |
Medium |
Positive |
1.1s |
0.9s |
1.1s |
Negative |
1.4s |
1.0s |
1.4s |
High |
Positive |
0.8s |
0.6s |
0.8s |
Negative |
1.0s |
0.7s |
1.0s |
Top | Back |
|

SL-1104 Overhead Ionizing Air Blower --- |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz |
Current Consumption |
1.66AMP or 0.83AMP |
Operating Temperature |
0~50 ¡æ |
Size |
1100mm(L) ¡Á 110mm(H) ¡Á 184mm(W) |
Weight |
11.7kg |
| Air Coverage |
40cm ¡Á 120cm |
Air Volume |
160~330CFM |
| Ion Balance |
0V ¡À 5V |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1kVto 100V
Temperature£º 22 ¡æ |
Distance |
300mm |
600mm |
900mm |
1200mm |
Left 300mm |
0.6s |
2.1s |
4.9s |
6.1s |
Centre |
0.6s |
1.9s |
4.2s |
5.7s |
Right 300mm |
0.7s |
2.1s |
4.7s |
6.0s |
Remarks:
1.Distance measured in mm, decay time measured in seconds.
2.Test data available using ME 268A Charged Plate Analyzer.
3.Test figures are subject to variation in the atmospheric conditions.
Top | Back |
|
 |
DC-001
Bench Top Ionizing Air Blower
Quickly neutralizes static charges, Excellent ion balance, Build ¨Cin emitter cleaner, Light and compact, it suits for machinery internal, working bench and production line. |
Specification:
Operating Voltage |
In: 220V Out: 15V |
Current Consumption |
220VAC/0.06A
|
Operating Temperature |
0~50¡æ |
| Air Speed |
2.0~3.3m/second |
Size |
180mm (L) x 200mm (H) x 75mm (W)
|
Weight |
1.0kg |
| Ozone Density |
£¼ 0.007ppm |
| Ion Balance |
0V ¡À 5V |
| Noise |
55dB |
| Air Volume |
Low 50CFM 2.5m/s
High 90CFM 4.0m/s
|
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1KVto 100V
Temperature £º 22 ¡æ |
Distance |
300mm |
600mm |
900mm |
Decay time |
0.5s-0.9s |
1.4s-1.8s |
4.0s-4.5s |
Top | Back |
|

|
DC-001A Warming Air Function Ionizing Air Blower |
Specification:
Operating Voltage |
110V/60Hz, 220V/50Hz |
Current Consumption |
2.1A or 4.2A |
Operating Temperature |
32¨H(0¡æ) ~ 122¨H(50¡æ) |
| Air Coverage |
30cm x 30cm |
Size |
240mm (L) x 180mm (W) x 100mm (H) |
Weight |
1.8kg |
| Air Volume |
50CFM~90CFM |
| Limited Power |
315W |
| Ion Balance |
0V¡À10V |
|
|
Top | Back |
|

|
DC-003 Overhead Ionizing Air Blower
Features:
Operating with DC current,
More light,
Three airflow output.
|
Specification:
Operating Voltage |
110V/60Hz,220V/50Hz |
Current Consumption |
1.66A or 0.83A |
Operating Temperature |
0~50¡æ |
| Air Coverage |
40cm x 120cm |
Size |
1180mm (L) x 155mm (W) x 110mm (H) |
Weight |
10kg |
| Air Volume |
160~330CFM |
| Ion Balance |
0V ¡À 5V |
|
Decay Test Results:
Distance |
Discharge Time |
Offset Volt |
300mm |
0.9s |
¡À 5V |
600mm |
2.4s |
¡À 5V |
900mm |
4.5s |
¡À 5V |
Top | Back |
|
 |
DC-110 Ionizing Air Blower |
Specification:
Operating Voltage |
110V/60Hz,220V/50Hz |
Current Consumption |
3.2A or 1.6A |
Operating Temperature |
0~50¡æ |
Size |
420mm (L) x 160mm (W) x 170mm (H) |
Weight |
5.6kg |
| Coverage Range |
80cm x 120cm |
| Ion Balance |
0V ¡À 5V |
| Air Volume |
70~120CFM |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1KVto 100V
Temperature £º 22 ¡æ |
Distance |
300mm |
600mm |
900mm |
Positive (+) |
0.9s |
2.1s |
3.5s |
Negative (-) |
1.0s |
2.3s |
3.8s |
Top | Back |
|

|
FC-001 Bench Top Ionizing Air Blower
Features:
Quickly neutralizes static charges
Excellent ion balance
Build-in emitter cleaner
Light and compact,
it suits for machinery internal, working bench and production line. |
Specification:
Operating Voltage |
90V-264V |
Current Consumption |
0.5A |
Operating Temperature |
0¡æ ~40¡æ |
| Air Coverage |
300mm ¡Á 300mm |
| Air Volocity |
90~120CFM |
Size |
75mm(L) ¡Á 160mm(W) ¡Á 200mm(H) |
Weight |
0.8kg |
| Ozone Density |
£¼0.007ppm |
| Ion Balance |
0V ¡À 5V |
Limited Power |
¡Ü10W |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 90V/264V
Testing Voltage£º 1KV ~ 100V
Temperature £º 22 ¡æ Rh£º 55 ~70% |
Distance |
|
300mm |
600mm |
900mm |
Decay time |
Positive(+) |
1.5s |
3.1s |
3.5s |
| |
Negative (-) |
1.7s |
3.4s |
4.0s |
Remarks:
1. Distance measured in mm, decay time measured in seconds.
2. Test data available using ME 268A Charged Plate Analyzer.
3. Test figures are subject to variation in the atmospheric conditions.
Top | Back |
|

|
ZH-001 Bench Top Ionizing Air Blower
ZHEN HUA ZH-001 Bench Top Ionizing Air Blower is static elimination device which deliver a balanced ion stream to neutralize wide, focused areas. It removes contaminants attraction and neutralize static charges from wide, focused, or hard to reach areas so as to increase productivity and yield in manufacturing. It is ideally used in industrial environments such as delicate electronic products, electronic assembly line, medical device manufacturing and assembly lines, printing, packaging, and small part injection molding. Its features are quickly neutralizes static charges, build-in emitter cleaner, adjustable speed control for airflow, indicator light for presence of ionization, integrated blower and power supply. The desk-top ionizing blower is a portable ionized air blower. It uses a small fan to produce air flow. The volume of air flow is controlled by a variable speed control which provides a wide range of air flow setting. |
Specification:
Operating Voltage |
110V/60Hz or220V/50Hz
|
Current Consumption |
0.25A or 0.12A
|
Operating Temperature |
0~50 ¡æ |
| Air Coverage |
40cm ¡Á 60cm |
Size |
90mm(L) ¡Á 260mm(H) ¡Á 170mm(W)
|
Weight |
3kg |
| Air Volume |
45~110CFM |
| Ion Balance |
+/- 10V |
|
Decay Test Results:
Testing Conditions |
Operating Voltage£º 110V/220V
Testing Voltage£º 1KVto 100V
Temperature £º 22 ¡æ |
|